- unique hybrid ceramic with a dual ceramic-polymer network structure
- available as mono- and multichromatic types in up to three translucency levels (T, HT, ST)
Register for MyVITA now
Recommended indications*
*) These are recommended indications; the entire range of single tooth restorations can normally be fabricated. For details, please refer to the respective working instructions of the products.
Blocks (mm):
Description | Prod. no. 5 pcs. |
---|---|
0M1-HT, EM-10 |
EC40M1HTEM10 8 x 10 x 15 mm |
0M1-HT, EM-14 |
EC40M1HTEM14 12 x 14 x 18 mm |
0M1-T, EM-14 |
EC40M1TEM14 12 x 14 x 18 mm |
1M1-HT, EM-10 |
EC41M1HTEM10 8 x 10 x 15 mm |
1M1-HT, EM-14 |
EC41M1HTEM14 12 x 14 x 18 mm |
1M1-T, EM-14 |
EC41M1TEM14 12 x 14 x 18 mm |
1M2-HT, EM-10 |
EC41M2HTEM10 8 x 10 x 15 mm |
1M2-HT, EM-14 |
EC41M2HTEM14 12 x 14 x 18 mm |
1M2-T, EM-14 |
EC41M2TEM14 12 x 14 x 18 mm |
2M2-HT, EM-10 |
EC42M2HTEM10 8 x 10 x 15 mm |
2M2-HT, EM-14 |
EC42M2HTEM14 12 x 14 x 18 mm |
2M2-T, EM-14 |
EC42M2TEM14 12 x 14 x 18 mm |
3M2-HT, EM-10 |
EC43M2HTEM10 8 x 10 x 15 mm |
3M2-HT, EM-14 |
EC43M2HTEM14 12 x 14 x 18 mm |
3M2-T, EM-14 |
EC43M2TEM14 12 x 14 x 18 mm |
2M1-T, EM-14 |
EC4EM3112765 12 x 14 x 18 mm |
2M3-T, EM-14 |
EC4EM3132765 12 x 14 x 18 mm |
3M1-T, EM-14 |
EC4EM3192765 12 x 14 x 18 mm |
3M3-T, EM-14 |
EC4EM3212765 12 x 14 x 18 mm |
4M2-T, EM-14 |
EC4EM3282765 12 x 14 x 18 mm |
2M1-HT, EM-10 |
EC4EM4112645 8 x 10 x 15 mm |
2M1-HT, EM-14 |
EC4EM4112765 12 x 14 x 18 mm |
2M3-HT, EM-10 |
EC4EM4132645 8 x 10 x 15 mm |
2M3-HT, EM-14 |
EC4EM4132765 12 x 14 x 18 mm |
3M1-HT, EM-10 |
EC4EM4192645 8 x 10 x 15 mm |
3M1-HT, EM-14 |
EC4EM4192765 12 x 14 x 18 mm |
3M3-HT, EM-10 |
EC4EM4212645 8 x 10 x 15 mm |
3M3-HT, EM-14 |
EC4EM4212765 12 x 14 x 18 mm |
4M2-HT, EM-10 |
EC4EM4282645 8 x 10 x 15 mm |
4M2-HT, EM-14 |
EC4EM4282765 12 x 14 x 18 mm |
1M1-ST, EM-14 |
EC4EM7062765 12 x 14 x 18 mm |
1M2-ST, EM-14 |
EC4EM7072765 12 x 14 x 18 mm |
2M2-ST, EM-14 |
EC4EM7122765 12 x 14 x 18 mm |
3M2-ST, EM-14 |
EC4EM7202765 12 x 14 x 18 mm |
4M2-ST, EM-14 |
EC4EM7282765 12 x 14 x 18 mm |
Description | Prod. no. 5 pcs. |
---|---|
0M1-HT, EM-10 |
EN1EM4022645 8 x 10 x 15 mm |
0M1-HT, EM-14 |
EN1EM4022765 12 x 14 x 18 mm |
0M1-T, EM-14 |
EN1EM3022765 12 x 14 x 18 mm |
1M1-HT, EM-10 |
EN1EM4062645 8 x 10 x 15 mm |
1M1-HT, EM-14 |
EN1EM4062765 12 x 14 x 18 mm |
1M1-T, EM-14 |
EN1EM3062765 12 x 14 x 18 mm |
1M2-HT, EM-10 |
EN1EM4072645 8 x 10 x 15 mm |
1M2-HT, EM-14 |
EN1EM4072765 12 x 14 x 18 mm |
1M2-T, EM-14 |
EN1EM3072765 12 x 14 x 18 mm |
2M2-HT, EM-10 |
EN1EM4122645 8 x 10 x 15 mm |
2M2-HT, EM-14 |
EN1EM4122765 12 x 14 x 18 mm |
2M2-T, EM-14 |
EN1EM3122765 12 x 14 x 18 mm |
3M2-HT, EM-10 |
EN1EM4202645 8 x 10 x 15 mm |
3M2-HT, EM-14 |
EN1EM4202765 12 x 14 x 18 mm |
3M2-T, EM-14 |
EN1EM3202765 12 x 14 x 18 mm |
4M2-HT, EM-10 |
EN1EM4282645 8 x 10 x 15 mm |
4M2-HT, EM-14 |
EN1EM4282765 12 x 14 x 18 mm |
4M2-T, EM-14 |
EN1EM3282765 12 x 14 x 18 mm |
1M1-ST, EM-14 |
EN1EM7062765 12 x 14 x 18 mm |
1M2-ST, EM-14 |
EN1EM7072765 12 x 14 x 18 mm |
2M2-ST, EM-14 |
EN1EM7122765 12 x 14 x 18 mm |
3M2-ST, EM-14 |
EN1EM7202765 12 x 14 x 18 mm |
4M2-ST, EM-14 |
EN1EM7282765 12 x 14 x 18 mm |
Description | Prod. no. 5 pcs. |
---|---|
1M1-HT, IS-16L |
EC4EM4069485 18 x 16 x 18 mm |
1M1-HT, IS-16S |
EC4EM4069365 18 x 16 x 18 mm |
1M1-T, IS-14L |
EC4EM3069725 18 x 14 x 12 mm |
1M1-T, IS-14S |
EC4EM3069605 18 x 14 x 12 mm |
1M2-HT, IS-16L |
EC4EM4079485 18 x 16 x 18 mm |
1M2-HT, IS-16S |
EC4EM4079365 18 x 16 x 18 mm |
1M2-T, IS-14L |
EC4EM3079725 18 x 14 x 12 mm |
1M2-T, IS-14S |
EC4EM3079605 18 x 14 x 12 mm |
2M2-HT, IS-16L |
EC4EM4129485 18 x 16 x 18 mm |
2M2-HT, IS-16S |
EC4EM4129365 18 x 16 x 18 mm |
2M2-T, IS-14L |
EC4EM3129725 18 x 14 x 12 mm |
2M2-T, IS-14S |
EC4EM3129605 18 x 14 x 12 mm |
3M2-HT, IS-16L |
EC4EM4209485 18 x 16 x 18 mm |
3M2-HT, IS-16S |
EC4EM4209365 18 x 16 x 18 mm |
3M2-T, IS-14L |
EC4EM3209725 18 x 14 x 12 mm |
3M2-T, IS-14S |
EC4EM3209605 18 x 14 x 12 mm |
4M2-HT, IS-16L |
EC4EM4289485 18 x 16 x 18 mm |
4M2-HT, IS-16S |
EC4EM4289365 18 x 16 x 18 mm |
4M2-T, IS-14L |
EC4EM3289725 18 x 14 x 12 mm |
4M2-T, IS-14S |
EC4EM3289605 18 x 14 x 12 mm |
VITAVM®LC
Light-curing, microparticle composite for extraoral use with fixed and removable restorations
VITA AKZENT® LC
Reliable reproduction of individual shade effects
VITA ENAMIC® Polishing Set
For simple pre- and high-gloss polishing of VITA ENAMIC hybrid ceramic
VITA ADIVA® FULL-ADHESIVE
The full-adhesive luting system with perfectly matched components for conditioning tooth substance and restorative material
VITA ADIVA® SELF-ADHESIVE
The self-adhesive luting system with perfectly matched components for conditioning the restorative material
VITA ENAMIC – SYSTEM SOLUTIONS*
VITA offers VITA ENAMIC with specific holder systems for the CAD/CAM systems:
VITA ENAMIC – UNIVERSAL SOLUTIONS*
*) Note: The range of VITA CAD/CAM material versions/geometries/shades available may vary for individual CAD/CAM system partners or systems. The hardware and software requirements in each case are available from the respective CAD/CAM system partners.
Declarations of conformity can only be accessed with MyVITA access. You can register for MyVITA by using the following link.
Register nowA dry treatment site must be provided for the adhesive bonding technique. Rubber dam and/or retraction cords are suitable for keeping the site dry. Please make sure that any excess bonding material is completely removed from the sulcus.
Conventional bonding using cements is contraindicated since sufficient load capacity and retention of the VITA ENAMIC crown on the abutment is only achieved by adhesive bonding.
....... and if so, how?
.... to repeat the application before continuing the work?
To ensure reliable bonding of abutment and crown, the abutment needs to be degreased with ethanol before further processing and the process step of "Priming" needs to be repeated.
..... Glaze or polished to high gloss?
Subgingival portions of the crown should be polished since a high-gloss surface of a crown reduces plaque accumulation.
Temporary bonding of VITA ENAMIC crowns to abutments is not recommended since the required load capacity is only guaranteed after definitive and firm bonding of the VITA ENAMIC crown.
.... (Al2O3) prior to bonding the crown? Is it also possible to sandblast with glass beads?
Defined surface enlargement and mechanical roughness are only achieved by sandblasting the abutment with Al2O3 prior to bonding the crown; in combination with the chemical compound (using a primer), reliable adhesive bonding of the crown to the abutment is achieved. Glass beads are not suitable for this purpose.
.... for adhesive bonding of VITA ENAMIC crowns to zirconia abutments?
These monomers in the primer/bonding agent and/or bonding composite enable chemical bonding of the sandblasted zirconia surface and the bonding material.
.... and what needs to be done in cases of screw loosening after bonding of the crown?
In such cases, simple trepanning of VITA ENAMIC crowns with a suitable milling or grinding tools can be carried out. Then prepare the access to the screw channel of the abutment. Tighten the prosthetic screw to the prescribed torque. Then follow the recommendations to seal the screw channel. Use phosphoric acid gel (30 sec) to clean the opening in the crown and then apply an adhesive/silane bonding agent. Light-curing restorative composites with high opacity are suitable to seal the opening. Please observe the corresponding instructions for use.
.... walls caused by a titanium abutment?
In such cases, high-opacity bonding materials with masking capacity should be used. Translucent adhesive materials, which are used, e.g. for veneers, are less suitable.
...... should be used?
To seal the screw channel, first apply gutta-percha, Teflon tape, or a similar material into the screw channel; then apply a suitable bonding agent into the opening and seal it tightly using a light-curing restorative composite.
The story of our single-visit ultrathin veneer challenge. With VITA ENAMIC.
December 25, 2017 by Hsuan Chen
CEREC Digest was founded in 2016 by Hsuan Chen (陳鉉) and Cheng-Han Li (李承翰). The plan was to create a channel that focuses on the CEREC system and dental CAD/CAM in general. The website was launched in January of 2017 as a joint effort between CEREC Asia, a training center based in Taiwan, and the Tooth Faerie Club, a 50-person study club created by Hsuan and Cheng-Han. The Digest caters primarily to the demographic of dentists and dental technicians who are interested to learn more about digital dentistry.