VITA vPad excellence - Say hello to the future.

VITA vPad excellence

Say hello to the future.

Control unit for:

  • VITA VACUMAT 6000 M
  • VITA VACUMAT 6100 M
  • VITA VACUMAT 6000 MP
  • VITA ZYRCOMAT 6000 MS
  • VITA ZYRCOMAT 6100 MS
  • VITA SMART.FIRE
  • VITA SMART.FIRE ADVANCED

Hardware:

  • Latest generation 10" touch display
  • SD card reader for transferring photos
  • Two USB ports for transferring data
  • Individually adjustable stand for optimal work with the device
  • 2 GB of storage for customer data (firing programs, photos, PDF files)

Software:

Operation of multiple furnaces

  • Use a VITA vPad excellence and the VITA SWITCHBOX to operate up to four furnaces

Guided initial setup

  • When starting for the first time, you will be guided through the initial setup. Once complete, the VITA firing system is perfectly adapted to your needs (Product video see download area)

Profile management

  • Creation of up to 12 customized users
  • Every user can be assigned a name, icon and color

Customizable desktops

  • Creation of up to 50 customized desktops per user with firing programs, photos and PDFs
  • Every desktop can be assigned a name and a color

Firing programs

  • Pre-installed firing programs for VITA materials and the most common CAD/CAM materials
  • Integrated working instructions for all VITA materials
  • Create new firing programs or modify existing firing programs

Digital assistance function

  • If necessary, you can use the step-by-step instructions integrated in the software
  • This supports you with features such as video and photo tutorials

Saves all firing data for quality assurance

  • The temperature gradient in the firing chamber is logged every time firing is carried out
  • Logged data can be exported to a USB flash drive or forwarded online directly to the VITA service team 

WiFi-enabled

  • Online update: Device software and pre-installed firing programs are always up to date
  • With an active WiFi connection, logged data can be forwarded online at the touch of a button directly to the VITA service team for analysis
  • Web browser

VITA FURNACE App (available for free from the Google Play Store)

  • Optimized time management, thanks to notification on a mobile device when firing is complete
  • Overview of time remaining until firing is complete
  • Transfer of images from a mobile device to the vPad

Data transfer

  • Profiles, firing programs and device data can be transferred to other VITA vPad comfort/excellence units or to a PC
  • Backup function for complete backup of all vPad data

Integrated photo and PDF viewer

  • View patient photos or PDF documents conveniently and directly on your vPad

Screensaver

  • Your custom images can be used as a template for the integrated screensaver

Multilingual

  • Menu navigation in 19 languages (German, English, French, Italian, Spanish, Bulgarian, Serbian, Croatian, Czech, Hungarian, Polish, Dutch, Finnish, Danish, Swedish, Russian, Turkish, Portuguese, Japanese)

VITA vPad excellence products

VITA vPad excellence
Description Prod. no.
VITA vPad excellence * Accessories: 1 connecting cable 1 Operating manual DVPADEXV1

VITA vPad excellence

Technical functions

  • Many service and control programs, e.g. automatic temperature adjustment before every start of the program, temperature sensor and vacuum control, fast cooling, night mode, power failure protection, display of operating hours for device and firing muffle, automatic cleaning
  • Function monitoring incl. logging of lift runs, pre-vacuum and main vacuum, temperature and time flows
  • Storage, backup and write protection of the individual user accounts and programs
  • Software update and data transfer to other vPad control units and to a PC via USB stick
  • Error monitoring with error display
  • Freely selectable lift positions for pre-drying, cooling and for fast cooling to standby temperature
  • Language selection

Technical data

Width 260 mm
Depth 150 mm
Height 200 mm
Weight 1,6 kg
Casing plastic
Classification Protection class 1

Temperature for operation: 10 C to 35 C
Humidity for operation: max. 80% RH
Application area: approved for indoor operation only

Accessories (can be purchased separately):

For the operation of 2 or more VITA VACUMAT 6000 M, VITA ZYRCOMAT 6000 MS, VITA ZYRCOMAT 6100 MS and VITA VACUMAT 6000 MP with one VITA vPad excellence a switchbox (Art. no. D65000) is required.

Product info

No. 10544 VITA Equipment Technical information (Version 002)

EN
FR
User manuals

No. 10098 VITA Screensaver (Version 001)

EN
FR

No. 10512 VITA vPad excellence (Version 002)

EN
FR
Brochures

No. 10101 VITA dental furnaces (Version 011)

EN
FR
Product video

initial setup / functional explanation VITA vPad excellence (Version 001)

EN
FR
Firing tables

VITA AKZENT Plus / 4000 PT / vPad com + ex + clin (Version 001)

EN
FR
Software and Software updates

150228 Update control units vPads (Version 002)

VITA vPad comfort / VITA vPad clinical up to serial number 2420155635
VITA vPad excellence up to serial number 2320152049

EN
FR

150228 Update Installation Instructions (Version 001)

VITA vPad comfort / VITA vPad clinical up to serial number 2420155635
VITA vPad excellence up to serial number 2320152049
VITA VACUMAT 6000 M
VITA VACUMAT 6000 MP
VITA ZYRCOMAT 6000 MS

EN
FR

180209 Software update VITA vPad comfort and VITA vPad excellence (Version 002)

VITA vPad comfort from serial number 2420155636 to 2420189999
VITA vPad excellence from serial number 2320152050 to 2320179999

EN
FR

230802 Softwareupdate VITA vPad excellence (Version 007)

EN
FR

Instructions for performing a software update (vPad excellence from 2820180275) (Version 001)

VITA vPad excellence from 2820180275
VITA VACUMAT 6000 M
VITA VACUMAT 6000 MP
VITA ZYRCOMAT 6000 MS
VITA ZYRCOMAT 6100 MS

EN
FR

Instructions for performing a software update (vPad excellence to 2820180274) (Version 001)

VITA vPad comfort from 3020180051
VITA vPad excellence from 2820170050 to 2820180274
VITA VACUMAT 6000 M
VITA VACUMAT 6000 MP
VITA ZYRCOMAT 6000 MS
VITA ZYRCOMAT 6100 MS

EN
FR

Firing programs VITA AMBRIA® and VITA LUMEX® AC (Version 001)

VITA vPad excellence up to serial number 2820172049
VITA vPad comfort up to serial number 3020180050

EN
FR

Update vPads help files (Version 001)

EN
FR

Easy download for multiple documents

Download a .zip file containing all the selected files in a single step.
Simply tick the files then click here.
VITA Update Messenger

VITA Update Messenger

Software updates as a free service

As a registered user, you can go to subscribe to the VITA Update Messenger. Upon request you will be informed about software updates for your VITA device from VITA Equipment servicing.

Subscribe right now!